From configuration to installation to operation and maintenance we work with.
Emergency generator room layout.
Getting air into and out of the room is critical and will impact placement.
Even the most reliable gen set after thousands of hours of operation will need some internal work.
Here are some other considerations.
Power designing emergency and standby generator systems consulting engineers who specify emergency and standby power equipment understand that installations for mission critical facilities such as hospitals and data centers are required to comply with nfpa 110.
Some driven equipment such as a generator in a large engine installation may require a dedicated ventilation source.
It is also important to consider all engine room equipment in the design of a ventilation system and provide a comfortable environment for service personnel to perform maintenance.
A well designed emergency generator set room provides sufficient space for maintenance and operation of equipment.
Generators require a lot of ventilation for cooling and combustion needs.
Look down the road to the day extensive gen set repairs may be needed.
Design of an engine room ventilation system.
See how our pieces will look in your home with the easy to use room designer tool.
If you are using a screen reader and are having problems using this website please call 877 266 7300 for assistance.
The ftr s should only be installed for the supply of fuel to emergency generator for fire service installation fsi or power backup for emergency building facilities essential service e g.
The generator room design must also comply with fire protection regulations.
National electrical code nec.
Skip to main content.
Emergency generator room design.
Multiple environmental factors come into play when designing a generator room.
Caterpillar offers the industry s widest range of diesel gas and rental generator sets automatic transfer switches uninterruptible power systems and switchgear.
We also know how to design a generator room to ensure optimum performance.
A backup generator set is an important line of defense for business owners.
Standard for emergency and standby power systems in conjunction with nfpa 70.
Generator room extracts from the canadian standards association 2015 section 6 11 emergency lighting 6 11 1 the emergency electrical power supply room and the automatic transfer switch room where separate shall be equipped with unit equipment for emergency lighting that complies with csa c22 2 no.
These include the environment in which the facility housing the generator is located in as well as the inner environment of the generator room itself.
The weight of a generator and the vibration experienced during its operation will have an impact on the building s structural design.